Communication Manager Maintenance-Object Repair Procedures
1574 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
57
FAIL
Hybrid Circuit test failed. This can result in noisy or bad connections.
1. Run circuit pack tests to check the Tone Generator circuit pack and 
the Tone Detector circuit pack, using test board location 
short
.
2. Resolve any problems that are detected on the Tone Generator 
circuit pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are functioning 
properly, and the test still fails, replace the MET Line circuit pack.
If the Hybrid Circuit and Conference Circuit test fails for every port on a 
circuit pack, a -5 Volt power problem is indicated. To investigate problems 
with a power unit, see 
PASS
Hybrid Circuit and Conference Circuit test passed. The hybrid circuitry is 
transmitting properly.
1. If complaints persist, investigate by using other port tests, and by 
examining the station, wiring, and connections.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board 
is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list 
config and resolve any problems that are found.
2. If the board was found to be inserted correctly, enter busyout 
board location.
3. Enter the reset board location command.
4. Enter the release board location command.
5. Enter test board location long
6. This should re-establish the linkage between the internal ID and the 
port. If this is not the case, check to ensure that there is a valid board 
inserted.
Table 581: Test #57 Hybrid Circuit and Conference Circuit Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 3 of 3