Avaya 03-300430 User Manual

Page of 2574
MET-LINE (MET Line)
Issue 1 June 2005
1575
 
MET Line Station Lamp Updates Test (#60)
For this test, the software lights the lamps on the terminal based on the status record contained 
in the processor. The lamp updates run only if the station is in-service.
Table 582: Test #60 MET Line Station Lamp Updates Test 
Error
Code
Test
Result
Description / Recommendation
1
ABRT
This port may have been busied out.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If 
this error type is present, then release the port using release 
station extension
 and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
2
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
3
ABRT
Station is in ready-for-service or out-of-service state. This may be due to 
wiring or an unplugged or defective set.
1. Make sure terminal is connected and the wiring is correct.
2. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available. The port may 
be busy with a valid call.
1. Use display port location to determine the station extension of 
the port. Use status station to determine the service state of the 
port. If the port is in use, wait until the port is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals 
up to 5 times.
FAIL
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
MET Line Station Lamp Updates completed successfully.
1. If complaints persist, investigate by using other circuit pack tests, and 
by examining the station, wiring, and connections.
 1 of 2