Avaya 03-300430 User Manual

Page of 2574
MET-LINE (MET Line)
Issue 1 June 2005
1577
 
Table 583: Test #61 MET Line Station Audits Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
Internal system error
1
ABRT
The test was aborted due to an internal system error during the 
switchhook audit.
2
The test was aborted due to an internal system error during the bad scan 
inquiry.
3
The test was aborted due to an internal system error during the EPF 
audit inquiry.
1. Make sure that the station is not in an out-of-service state.
2. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available. The port 
may be busy with a valid call.
1. Use display port location to determine the station extension 
of the port. Use status station to determine the service state of 
the port. If the port is in use, wait until the port is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals 
up to 5 times.
1004
ABRT
The port was seized by a valid call during the test. The test has been 
aborted.
1. Use display port location to determine the station extension 
of the port. Use status station to determine the service state of 
the port. If the port is in use, wait until the port is idle before testing.
2. Retry the command at 1-minute intervals up to 5 times.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The test failed due to an internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 2