Avaya 03-300430 User Manual

Page of 2574
MED-GTWY (MEDIA GATEWAY)
Issue 1 June 2005
1581
 
MED-GTWY (MEDIA GATEWAY)
S8700 | 8710
 / 
S8500
 / 
S8300
 / 
G700
The MEDIA GATEWAY maintenance object monitors the H.248 link to the Avaya G700 Media 
Gateway. It logs errors when the Keep Alive messages that are exchanged between the server 
and G700 fail. These messages indicate the status of the H.248 link between the two. If the 
Keep Alive messages are active all is well, if not an error is logged.
Error log entries and test to clear values
Notes:
a. Error Type 1: failure of the H.248 link keep alive messages between the server and the 
G700. This is an indication that the LAN or the platform is down.
b. Error Type 257: If the server is an LSP, at least one Media Gateway is registered with the 
LSP.
c. Error Type 513: there is a problem on the G700. Log on to the G700 and check the error 
log for problems using the MGP CLI.
d. Error Type 769 is a transient error, indicating that the link has unregistered with the G700. If 
the G700 re-registers, the alarm is resolved. If the link loss delay timer on the primary server 
expires, Error Type 1 is logged.
MO Name in 
Alarm Log
Alarm
Level
Initial Command to Run
Full Name of MO
MED-GTWY
MAJ
test board location
MEDIA GATEWAY
Table 585: MED-GTWY error log entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
1 (
None
MAJ
OFF
257 (
)
None
MAJ
OFF
513 (
None
MAJ
ON
769 (
)
None
MIN
OFF