Communication Manager Maintenance-Object Repair Procedures
1590 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 1: the circuit pack stopped functioning or is physically removed from the system.
This alarm logs approximately 11 minutes after removing the circuit pack and/or the SAKI 
Sanity Test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack in the same slot as the error 
indicates. See note (g).
c. Error Type 257: transient communication problems between the switch and this circuit 
pack. Execute the test board location command and refer to the repair procedures 
for the Control Channel Loop Around Test (#52).
d. Error Type 513: on-board hardware failure. Aux data values correspond to the following 
detected errors:
Reset the circuit pack with the busyout board location and reset board 
location
 commands. When reset, the circuit pack executes a set of tests to detect the 
presence of any of the faults listed above. Detection of one of these errors during 
initialization causes the circuit pack to lock-up and appear insane to the system.
1291 (
)
4359
Clear Error 
Counters 
(#270)
MIN
ON
3586 (
)
MIN
OFF
3840 (
)
4096 to
4101
3842 (
)
46095
3843 (
)
46097
Aux Value
Detected Error
4352
External RAM error
4353
Internal RAM error
4355
ROM checksum error
4357
Instruction set error
Table 588: MG-BRI Error Log Entries and Test to Clear Values  (continued)
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off 
Board
Test to Clear Value
 2 of 2