Avaya 03-300430 User Manual

Page of 2574
MG-DS1 (DS1 Interface Media Module)
Issue 1 June 2005
1603
 
System Technician-Demanded Tests: Descriptions and Error 
Codes
Investigate tests in the order they are presented. By clearing Error Codes associated with the 
Echo Cancellation Test you may also clear errors generated from other tests in the sequence.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
Reset 
Board 
Sequence
test 
ds1-loop
D/ND
1
1. D = Destructive; ND = Nondestructive
Echo Cancellation Test (#1420)
X
D
Control Channel Loop Test (#52)
X
ND
NPE Connection Audit Test (#50)
Aborts with Error Code 1412
Loss of Signal Alarm Inquiry (#138)
X
X
ND
Blue Alarm Inquiry Test (#139)
X
X
ND
Red Alarm Inquiry Test (#140)
X
X
ND
Yellow Alarm Inquiry Test (#141)
X
X
ND
Major Alarm Inquiry Test (#142)
X
X
ND
Minor Alarm Inquiry Test (#143)
X
X
ND
Slip Alarm Inquiry Test (#144)
X
X
ND
Misframe Alarm Inquiry Test (#145)
X
X
ND
Translation Update Test (#146)
X
X
ND
SAKI Sanity Test (#53)
 
 
X
D
Internal Looparound Test (#135)
Aborts with Error Code 1412
X
D