Avaya 03-300430 User Manual

Page of 2574
MG-DS1 (DS1 Interface Media Module)
Issue 1 June 2005
1633
 
1 to 88
(
cont’d
)
FAIL
(
cont’d
)
If the MM710 connects to a line-side terminating device (for example, a 
PRI terminal adapter), do the following:
1. Retry the command at 1-minute intervals for a maximum of 5 
times.
2. Enter the list measurement ds1-log location command 
to read the error seconds measurement.
3. Verify that the switch DS1 and the line-side terminating device are 
administered using the same signaling mode, framing mode, and 
line coding.
4. Investigate the maintenance status of the line-side terminating 
device. Refer to the 'Line-Side Terminating Device Operating 
Manual' for information.
5. Check the physical connection of the MM710 interface Media 
Module to the terminating device, and check the premise 
distribution system (or the intra-premise wiring) for physical 
connection failures.
6. Replace the local MM710 interface Media Module and repeat the 
test.
7. Contact the vendor of the line-side terminating device to diagnose 
the equipment.
 
PASS
No Slip alarm is detected on the MM710 Interface Media Module.
Table 598: TEST #144 Slip Alarm Inquiry Test (continued)
Error
Code
Test
Result
Description/ Recommendation
 3 of 4