Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1636 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1 to 17 
FAIL
The test failed because the MM710 interface Media Module detected 
errors in the received framing bits pattern. The Error Code equals the 
number of misframes detected by the MM710 interface Media Module 
since the last misframe alarm inquiry test. Major bit and minor bit error 
rate (error types 2561 and 2817) error logs often accompany misframe 
alarms. Clearing the cause of these error logs may clear the misframes 
which are occurring.
If the MM710 connects to a T1 network facility or to another switch, do 
the following:
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. Enter  list measurement ds1-log GGGVS to read the error 
seconds measurement.
3. Verify that both endpoints of the DS1 link are administered using 
the same signaling mode, framing mode, and line coding.
4. Check the physical connectivity of the MM710 interface Media 
Modules and the cable.
5. Replace the local MM710 interface Media Module, and repeat the 
test.
6. Contact T1 Network Service or the technician at the remote switch 
to diagnose the remote DS1 endpoint.
Table 599: TEST #145 Misframe Alarm Inquiry Test  (continued)
Error
Code
Test
Result
Description/ Recommendation
 2 of 4