MG-DS1 (DS1 Interface Media Module)
Issue 1 June 2005
1637
 
1 to 17 
(
cont’d
)
FAIL
If the MM710 connects to a line-side terminating device such as a PRI 
terminal adapter:
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. Enter list measurement ds1-log GGGVS to read the error 
seconds measurement.
3. Verify that the switch DS1 and the line-side terminating device are 
administered using the same signaling mode, framing mode, and 
line coding.
4. Investigate the maintenance status of the line-side terminating 
device. Refer to the 'Line-Side Terminating Device Operating 
Manual' for information.
5. Check the physical connection of the MM710 interface Media 
Module to the terminating device, and check the premise 
distribution system (or the intra-premise wiring) for physical 
connection failures.
6. Replace the local MM710 interface Media Module and repeat the 
test.
7. Contact the vendor of the line-side terminating device to diagnose 
the equipment.
 
PASS
No Misframe alarm is detected on the MM710 Interface Media Module.
Table 599: TEST #145 Misframe Alarm Inquiry Test  (continued)
Error
Code
Test
Result
Description/ Recommendation
 3 of 4