Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1638 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Any
NO
BOARD
The test could not relate the internal ID to the port (no board). This 
could be due to incorrect translations, no board is inserted, an incorrect 
board is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the add 
ds1 location command to administer the MM710 interface if it is 
not already administered.
2. If the board was already administered correctly, check the error log 
to determine whether the board is hyperactive. If this is the case, 
the board is shut down. Reseating the board will re-initialize the 
board.
3. If the board was found to be correctly inserted in step 1, then enter 
the busyout board location command.
4. Enter the reset board location command.
5. Enter the release board location command.
6. Enter the test board location long command. 
This should re-establish the linkage between the internal ID and the port.