Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
1646 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
System Technician-Demanded Tests:
Descriptions and Error Codes
Descriptions and Error Codes
Investigate tests in the order presented below. Clearing error codes associated with one test
may also clear errors generated from other tests in the sequence.
may also clear errors generated from other tests in the sequence.
NPE /NCE Audit Test (#50)
This test is not applicable to media modules and will always abort.
Order of Investigation
Short Test
Sequence
Sequence
Long Test
Sequence
Sequence
Reset
Board
Sequence
Board
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
NPE Audit Test (#50)
G250
G250-BRI
G350
: Aborts with Error Code
1412 on G700/G350/G250
X
ND
Ringing Application Test (#51)
G250
G250-BRI
G350
: Aborts with Error Code
1412 on G700/G350/G250
X
X
ND
Control Channel Loop Test (#52)
X
X
Flow Control Update (#1)
G250
G250-BRI
G350
: Always passes on G700/
G350/G250
X
X
ND
Neon Test (#220)
G250
G250-BRI
G350
: Aborts with Error Code
1412 on G700/G350/G250
X
X
ND
Table 603: Test #50 NPE Audit
Error
Code
Code
Test
Result
Result
Description / Recommendation
1412
ABRT
1. This test is not run on media modules and will always abort.