Avaya 03-300430 User Manual

Page of 2574
MMI-BD
Issue 1 June 2005
1657
 
Figure 91: Typical ESM connections
!
CAUTION:
CAUTION:
The TN2207 circuit pack is the only pack that allows connection of an ESM to 
S8700 Media Server configurations.
Error Log Entries and Test to Clear Values
Figure notes:
1.
Port B Y-cable connector to a TN787 
MMI (Multimedia Interface) circuit 
pack
5.
D8W cord connected to 356A 
adapter port 1
2.
Port A Y-cable connector to a 
TN2207 PRI circuit pack
6.
Expansion Service Module (ESM)
3.
25-pair Y-cable
7.
Port B on compatible PRI (primary 
rate interface) card
4.
356A adapter
cydf012 KLC 092801
4
5
3
6
7
8
1
2
Table 613: MMI-BD Error Log Entries 
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0 (
0
Any
Any
Any
test board location sh r 1
1 (
Any
None
MIN
ON
18 (
0
busyout board 
location
WRN
OFF
release board location
217 (
)
0
None
WRN
ON
 1 of 2