Communication Manager Maintenance-Object Repair Procedures
1658 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 1: the circuit pack stopped functioning or it was physically removed from the 
system. The alarm logs approximately 11 minutes after the circuit pack has been removed 
and/or the SAKI Sanity test (#53) fails.
If the circuit pack is in the system and the red LED is on, follow the instructions for a red 
alarm in 
c. Error Type 18: the circuit pack was busied out using busyout board location.
d. Error Type 217: there are more than four MMI circuit packs in the system. Remove the 
circuit pack that generated the error in the error log by locating the slot indicated by the 
error.
e. Error Type 257: there are transient communication problems between the switch and this 
circuit pack. Execute test board location and see the repair procedures for the 
Control Channel Loop-around test (#52) in 
257 (
)
65535
Control Channel 
Loop test (#52)
MIN
ON
test board location r 3
513 (
)
4352 
to 4357
Uplink error from 
circuit pack
769 (
)
Any
MMI 
Synchronization 
Status (#1123)
1281 (
) Any
Circuit Pack 
Restart test 
(#594)
MAJ
ON
1538 (
Any
Software detected 
error
MIN
ON
1793 (
Any
TSI XTalk (#6)
MIN
ON
test board location l r 3
2049 (
Any 
TSI Loop (#1108)
MAJ
ON
test board location l r 3
Table 613: MMI-BD Error Log Entries  (continued)
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
 2 of 2