Avaya 03-300430 User Manual

Page of 2574
MMI-BD
Issue 1 June 2005
1659
 
f. Error Type 513: the circuit pack detected an Angel on-board hardware failure. The reported 
Aux Data values correspond to the following detected errors:
4352 — External RAM error
4253 — Internal RAM error
4355 — ROM Checksum error
4357 — Instruction set error
Use busyout board locationreset board location, and release board 
location
. When reset, the circuit pack executes a set of tests to detect the presence of 
any of the above faults. The detection of one these errors during initialization causes the 
circuit pack to lock up and appear insane to the system. See the repair procedures in Note 
(
) for Error Type 1.
g. Error Type 769: this MMI circuit pack reported a loss of MMI synchronization. Refer to 
Test #1123 for repair procedures.
h. Error Type 1281: a failure of the time slot interchanger was detected. Reset the circuit pack 
using busyout board locationreset board location, and release board 
location
. If the reset passes, then the on-board circuitry is healthy. Retire the alarm using 
test board location long clear followed by release board location.
i. Error Type 1538: the circuit pack is hyperactive and it is flooding the switch with messages 
sent over the control channel. The circuit pack is taken out-of-service when a threshold 
number of these errors is reported to the switch. Clear the alarm using busyout board 
location
reset board locationtest board location long clear, and 
release board location. If the error recurs within 10 minutes, replace the circuit pack.
j. Error Type 1793: the TSI Cross Talk test (#6) failed. See the description of this test, and 
follow its repair procedures.
k. Error Type 2049: the TSI Loop-around test (#1108) failed. See the description of this test, 
and follow its repair procedures.