Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1688 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Modem Pool Conversion Resource Loop-
Around Test (#98)
The Modem Pool Conversion Resource Loop-Around test is set up as follows:
Figure 95: Modem Pool Conversion Resource Loop-Around
None
FAIL
The test failed. This error is internal to the Pooled Modem circuit pack 
and does not involve external equipment or interfaces.
1. Busyout both of the TN758 Pooled Modem conversion resources on 
the circuit pack containing the failing conversion resource.
2. If the test continues to fail, replace the Pooled Modem circuit pack 
and retest.
Any
FAIL
The Network Processing Element (NPE) of the tested port did not 
conference the tones correctly. This will cause noisy and unreliable 
connections.
1. If the remaining ports are currently idle (amber LED is off), reset the 
circuit pack and repeat the test.
2. If the test fails again, replace the circuit pack.
PASS
The port can correctly conference multiple connections. User-reported 
troubles on this port should be investigated using other port tests and by 
examining station, trunk, or external wiring.
Table 623: Test #97 Modem Pool Conference Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 3 of 3
TS-A
TS-C
ANALOG
PORTION
DIGITAL
PORTION
MAINTENANCE/
TEST BOARD
(TN771B)
DIGITAL
PORT
MODEM POOL CONVERSION RESOURCE
TN758 POOLED MODEM CIRCUIT PACK
TS-B