Avaya 03-300430 User Manual
M/T-ANL (Maintenance/Test Analog Port)
Issue 1 June 2005
1697
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its procedures. This Error Code
appears in the Error Log only if the MTB circuit pack has been removed since the Error Log
was last cleared. Verify that the circuit pack has been reinserted.
appears in the Error Log only if the MTB circuit pack has been removed since the Error Log
was last cleared. Verify that the circuit pack has been reinserted.
b. Error Type 1: a hardware failure on the Analog Port circuitry. Replace the Maintenance/Test
circuit pack if the command does not resolve the alarm.
c. Error Type 3840: call processing records did not agree with on-board records for the hook
state (on-/off-hook) of the Maintenance/Test analog port. This error is not service-affecting
and no action is required.
and no action is required.
Table 626: M/T-ANL Error Log Entries
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/Off
Board
Board
Test to Clear Value
)
0
Any
Any
Any
test port location
)
41018
none
MIN
ON
test port location l r 3
18
0
busyout port
location
WRN
OFF
release port location
257
Any
NPE Crosstalk test
(#9)
MIN
ON
test port location l r 3
513
Any
Analog Port Sanity
test (#963)
MIN
ON
test port location r 2
769
Any
Analog Port Digital
Loop-around (#13)
MIN
ON
test port location r 3
3840 (
)
Any
Hook State Inquiry
test (#566)