Avaya 03-300430 User Manual

Page of 2574
M/T-ANL (Maintenance/Test Analog Port)
Issue 1 June 2005
1699
 
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out of service due to 
TDM-BUS errors. A system is considered under heavy traffic when the Call 
Processing Occupancy is greater than 50% or when the System 
Management and the Call Processing Occupancies together exceed 65%. 
To view the system occupancy measurements enter status health on 
the system technician terminal.
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
repeat test at 1-minute intervals up to 3 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of tone detectors present or some tone 
detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 3 
times.
1004
ABRT
The port has been seized by a valid ATMS test call.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to abort and the port is idle on a valid ATMS test 
call, escalate the problem. To determine whether the port is in use by 
an ATMS test call, enter status station ext where ext is the 
assigned ATMS station’s number.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
Table 627: Test #9 NPE Crosstalk Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 3