Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
1706 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Hardware Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 1: the circuit pack has stopped functioning. Reset the circuit pack using
busyout board location, reset board location, and release board
location. If the SAKI Sanity test (#53) passes, the on-board circuitry is healthy. If the
location. If the SAKI Sanity test (#53) passes, the on-board circuitry is healthy. If the
SAKI Sanity test (#53) fails, replace the circuit pack.