Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1720 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
101
FAIL
Data was not sent from port 3 to port 2 successfully in asynchronous 
mode.
1. Reset the circuit pack using busyout board locationreset 
board location, and release board location.
2. Test the port again using test port location (02) l.
3. If the test fails again, replace the circuit pack.
102
FAIL
Data was not sent from port 2 to port 3 successfully in synchronous 
mode.
1. Reset the circuit pack using busyout board locationreset 
board location, and release board location.
2. Test the port again using test port location (02) l.
3. If the test fails again, replace the circuit pack.
103
FAIL
Data was not sent from port 3 to port 2 successfully in synchronous 
mode.
1. Reset the circuit pack using busyout board locationreset 
board location, and release board location.
2. Test the port again using test port location (02) l.
3. If the test fails again, replace the circuit pack.
PASS
The Maintenance/Test digital port digital trunk testing capability is 
operating correctly.
Table 636: Test #565 Digital Port Sanity Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 3 of 3