Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1746 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1000
ABRT
The test was aborted because system resources required to run this 
test were not available. The port may be busy with a valid call.
1. Use display port location to determine the station extension 
of the port. Use status station to determine the service state of 
the port. If the service state indicates that the port is in use, then the 
port is unavailable for certain tests. You must wait until the port is 
idle before retesting.
2. If the port is idle, retry the command at 1-minute intervals up to 5 
times.
1006
ABRT
The test was aborted because the station is out of service. This 
condition may be accompanied by an error type 18 entry in the error 
log. You may want to determine why the station was taken out of 
service. (When stations are taken out of service by maintenance 
software, the problems that preceded that point must be cleared.)
1. Use status station to check the service state of the port. If the 
port is indeed out of service, enter release station to bring the 
station back into service.
2. Retry the command at 1-minute intervals up to 5 times.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. If the test aborts with Error Code 2000 again, run short test 
sequence on the associated DS1-BD or UDS1-BD. If tests 138 
through 145 on the associated DS1-BD or UDS1-BD are also 
aborting with Error Code 2000, hyperactivity on the board or facility 
is indicated. In this case, the hyperactivity problem should be dealt 
with first.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
7 or 8
FAIL
Test failed due to internal system error. Do not replace port board.
Error code 7: the failure occurred during station translation download (to 
DS1 Interface circuit pack).
Error code 8: the failure occurred during station ringer update.
1. Retry the command at 1-minute intervals up to 5 times.
Table 646: Test #36 Audit and Update Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 3