Avaya 03-300430 User Manual

Page of 2574
OPS-LINE (DS1 Off-Premises Station Line)
Issue 1 June 2005
1747
 
PASS
Trunk translation has been updated successfully. The current trunk 
states kept in the DS1 Interface circuit pack and switch software are 
consistent. 
If the trunk is busied out, the test will not run but will return PASS. To 
verify that the station is in-service:
1. Enter status station to verify that the station is in-service. If the 
station is in-service, no further action is necessary. If the station is 
out-of-service, continue to step 2.
2. Enter release station to put the station back into in-service.
3. Retry the test command.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This 
could be due to incorrect translations, no board is inserted, an incorrect 
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list 
config, and resolve any problems that are found.
2. If the board was found to be inserted correctly, enter busyout 
board location.
3. Enter the reset board location command.
4. Enter the release board location command.
5. Enter test board location long.
This should re-establish the linkage between the internal ID and the 
port. If not, ensure that there is a valid board inserted.
Table 646: Test #36 Audit and Update Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 3 of 3