Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1750 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This 
could be due to incorrect translations, no board is inserted, an incorrect 
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list 
config, and resolve any problems that are found.
2. If the board was found to be inserted correctly, enter busyout 
board location.
3. Enter the reset board location command.
4. Enter the release board location command.
5. Enter test board location long
This should re-establish the linkage between the internal ID and the 
port. If not, ensure that there is a valid board inserted.
Table 647: Test #312 DS1 OPS Switchhook Inquiry Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 3 of 3