Avaya 03-300430 User Manual

Page of 2574
PDMODULE (Processor Data Module)
Issue 1 June 2005
1757
 
determine the state of the data module. The off-hook should have changed the service state 
to in-service. No action is necessary.
k. Error Type 2305, Aux Data 40967: the link between the circuit pack and the data module 
has been reset successfully. The link is normally reset when the circuit pack associated with 
an administered port is first plugged in (assuming that the data module is already in place 
and connected to the associated port), when a port is first administered (assuming the 
associated circuit pack is plugged in and that the data module is connected to the 
associated port), or when a data module is first connected to an administered port. No 
system technician action is necessary.
l. Error Type 2561: the downlink buffer on the circuit pack has overflowed. No action is 
necessary.
m. Error Type 2817: a DCP endpoint may have been disconnected.
n. Error Type 1, 769, 1537, 3841: make sure the data module is connected and operating 
properly. Check for faulty wiring. If necessary, reduce the length of the cable between the 
data module and the switch to 5000 ft. for 24-gauge wire or 4000 ft. for 24-gauge wire.
If the problem still exists, replace the circuit pack. Once the problem has been resolved, the 
alarm will be retired in 60 minutes (90 min. for error 1537). (These error counters use the 
leaky bucket mechanism.)
The DA module is not phantom-powered from the port. Thus when it is in linked mode, its 
range is limited by the Italtel digital phone’s limit: 0.7 Km (2300 ft.) on 26-gauge wire or 1.8 
Km (5900 ft.) on 22-gauge (0.6 mm) wire. If in stand-alone mode, it is limited by the 
maximum length of loop allowed from the Digital Line Interface (DLI) component: up to 3.5 
km (2 miles) on 22-gauge (0.6 mm) wire.
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented below. Clearing Error Codes associated with the one 
test may also clear errors generated from other tests in the sequence.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Data Module Internal Loop-around test (#175)
G700
: Aborts with Error Code 1412 on a G700 media gateway.
X
ND
Digital Port Board Network Processing Element Crosstalk test 
(#9)
X
ND
 1 of 2