Avaya 03-300430 User Manual
PDMODULE (Processor Data Module)
Issue 1 June 2005
1767
Table 654: Test #175 Data Module Internal Loop-Around Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
S8700 | 8710
/
S8500
1000
ABRT
System resources required to run this test are not available. The port may
be in use on a valid call. Use status data-module to determine when
be in use on a valid call. Use status data-module to determine when
the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABRT
Loop around testing is not enabled on the data module administration
screen.
screen.
1. Set Loop-Around Test field to y on the data module administration
screen.
1042
ABRT
The port under test is a TTI port and thus has only default translations
and no assigned extension. The test requires an extension assigned to
the port being tested.
and no assigned extension. The test requires an extension assigned to
the port being tested.
1. If there is a need to execute the test on this particular port, then you
must fully administer the port so that is has an assigned extension.
1180
ABRT
A Maintenance/Test circuit pack digital port is not available to carry out
the test.
the test.
1. See if the Maintenance/Test digital ports are present. Use list
config board location and look for ports 02 and 03.
2. If the digital ports (02 and 03) on the M/T-BD are absent, see
3. If the digital ports are present, try the command again at 1-minute
intervals up to 5 times.
1181
ABRT
No time-slots available to connect digital ports for the test.
1. Try the command again at 1-minute intervals up to 5 times.
1182
ABRT
Internal system error. Failed to connect the digital ports with time-slots.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 6