Avaya 03-300430 User Manual

Page of 2574
PE-BCHL (PRI Endpoint Port)
Issue 1 June 2005
1785
 
Audit and Update Test (#36)
This test sends port level translation data from switch processor to the UDS1 interface circuit 
pack to assure that the port’s translation is correct. The port audit operation verifies the 
consistency of the current state of port kept in the UDS1 interface circuit pack and in the switch 
software.
Table 660: Test #36 Audit and Update Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABRT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Test failed due to internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Port translation has been updated successfully. The current port states 
kept in the UDS1 interface circuit pack and switch software are consistent. 
If the port is busied out, the test will not run, but will return PASS. To verify 
that the port is in-service:
1. Enter status pri-endpoint extension to verify that the port is 
in-service. If the port is in-service, no further action is necessary. If the 
port is out-of-service, continue to Step 2.
2. Enter release pri-endpoint extension or release port 
location command to put port back into in-service.
3. Retry the test command.