PKT-INT (Packet Interface)
S8700 | 8710
 / 
S8500
The Packet Interface (PKT-INT) MO resides on the TN2312 IP Server Interface (IPSI) circuit 
pack and serves as an interface between the media server and the packet bus.
The TN1655 PKT-INT and TN2182 Tone-Clock circuit packs’ functions are on the TN2312 IPSI 
circuit pack. The IPSI circuit pack also provides:
PKT-INT packet-bus interface
Archangel TDM-bus interface
Tone-Clock functionality
Ethernet interface for connectivity to media servers
Ethernet interface for connectivity to services laptop PCs
S8700 MC
: Maintenance board interface for communication with the PN’s Maintenance 
board, in Carrier A or B only
The TN2312 IPSI circuit pack is inserted into a PN’s Tone-Clock slot and provides an Ethernet 
interface back to the media servers. The PKT-INT interface module on the IPSI is like previous 
DEFINITY TN1655 PKT-INT boards. However, the IPSI’s PKT-INT module does not support 
DMI Mode-2/-3 data or BX.25 links.
The PKT-INT supports links used for call setup of every port located in a PN. Packet Interface 
failure prevents call set-up and tear-down from telephones and trunks connected to PNs.
In addition to affecting telephone service, Packet Interface failure affects the service provided 
by circuit packs that connect to the Packet bus. For example:
TN464, TN2207, TN2464 Universal DS1 circuit pack 
 ISDN-PRI service
TN556, TN2198, TN2185 ISDN-BRI Line circuit pack 
 ISDN-BRI service
S8700 MC
: TN2305, TN2306 ATM
S8700 MC
: TN570 Expansion Interface (EI)
S8700 MC
: TN573 Switch Node Interface (SNI)
TN799DP Control LAN (C-LAN) packet port circuit pack
TN2501 Voice Announcements over the LAN (VAL)
MO Name in 
Alarm Log
Alarm 
Level
Initial SAT Command to Run
Full Name of MO
PKT-INT
MAJ
reset packet-interface location
Packet Interface
PKT-INT
MIN
test packet-interface location
Packet Interface
PKT-INT
WRN
test packet-interface location
Packet Interface