Avaya 03-300430 User Manual

Page of 2574
PKT-INT (Packet Interface)
Issue 1 June 2005
1813
 
For a case where not every link appears in the Failed Links category, examine the alarm 
and error logs for failures of the following circuit packs, and follow the repair procedures for 
those circuit packs before considering replacing the associated IPSI circuit pack:
S8700 MC
: TN570 Expansion Interface circuit pack (EXP-INTF)
S8700 MC
: TN573 Switch Node Interface circuit pack (SNI-BD)
S8700 MC
: Switch Node Clock circuit pack (SNC-BD)
ISDN-BRI Line circuit packs, ports, and stations (BRI-BD, BRI-PORT, BRI-SET)
Universal DS1 circuit packs and ports (UDS1-BD, TIE-DS1)
TN464, TN2207, TN2464 Universal DS1 circuit pack 
 ISDN-PRI service
TN556, TN2198, TN2185 ISDN-BRI Line circuit pack 
 ISDN-BRI service
TN2305, TN2306 ATM
TN799DP Control LAN (C-LAN) packet port circuit pack
TN2501 Voice Announcements over the LAN (VAL)
Use test sys-link with the faulted path option to test all components in the faulted link.
Error Log Entries and Test to Clear Values
Table 668: Packet Interface Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0 (
0
Any
Any
ON
test packet-interface 
location l r 2
1 (
Any
None
MAJ
ON
reset packet-interface 
location
1
10 (
0
None
50 (
0
None
257 (
Any
None
MAJ
ON
reset packet-interface 
location
513 (
Any
None
MAJ
ON
reset packet-interface 
location
769
770 (
Any
Maintenance 
Loop-Around test 
(#886)
MAJ
ON
test packet-interface 
location  s r 2
 1 of 2