Issue 1 June 2005
1825
 
Maintenance Loop-Around Test (#886)
This test checks whether an IPSI circuit pack’s Packet Interface module correctly sends and 
receives data. It establishes a LAPD link from the IPSI’s Packet Interface module back to the 
same Packet Interface module, and transmits and receives test data over that testing link. While 
timing signals from the packet bus are used for the data transfer, the data itself is looped around 
on the circuit pack at the interface to the packet bus and does not get sent over the packet bus.
Note:
Note:
In a high- or critical-reliability system (duplicated IPSIs), this test does not run on 
a standby IPSI’s Packet Interface module. However, a failure of the Maintenance 
Loop-Around test may cause an IPSI interchange that reports an alarm 
(associated with the loop-around failure, Error Code 769) against the standby 
IPSI’s Packet Interface module. If so, and if every other Packet Interface test in 
test packet-interface location long sequence passes, use set 
ipserver-interface
 to force the standby IPSI to go active. Then, use test 
packet-interface location
 to run the Maintenance Loop-Around test, and 
verify that the problem cleared.
Table 671: Test #886 Maintenance Loop-Around Test 
Error 
Code
Test 
Result
Description / Recommendation
1006
1137
ABRT
Because the IPSI circuit pack’s Packet Interface module is out of service, 
normal maintenance tests do not run on that Packet Interface.
1. Use reset packet-interface location to reset the Packet 
Interface.
For further action, see the repair procedures in 
on page 1836 for the Packet Interface Reset test (#889).
1139
ABRT
The packet bus is alarmed.
1. Try to retire the alarm associated with the packet bus. Use display 
alarms to see the Alarm Log. Refer to the maintenance 
documentation for Packet Bus maintenance for further action.
2. Retry the command when the alarm associated with the packet bus is 
retired.
1335
ABRT
Internal IPSI error. Because the Packet Interface module is on the standby 
IPSI, this test is not allowed to execute.
1. Use set ipserver-interface location to make the standby 
Packet Interface active.
2. Run the test.
 1 of 4