Avaya 03-300430 User Manual

Page of 2574
PKT-INT (Packet Interface)
Issue 1 June 2005
1829
 
Running this test on the active IPSI circuit pack’s Packet Interface module reads and clears the 
Parity Error counter and FIFO Overflow counter. 
S8700 MC
: Those counters are not used when a 
Packet Interface module is in standby mode.
S8700 MC
: Running this test on the standby IPSI circuit pack’s Packet Interface module, reads 
but does not clear a Translation RAM counter. The Translation RAM counter is not cleared since 
the number of bad translation RAM locations indicates bad locations that cannot be used. 
For an active Packet Interface module, information about the number of bad Translation 
locations is sent to maintenance software as an in-line error from the IPSI circuit pack, so it is 
not necessary to read a counter location.
Table 672: Test #887 Read and Clear Board Counters 
Error 
Code
Test 
Result
Description / Recommendation
1006
1137
ABRT
The IPSI circuit pack’s Packet Interface module is out of service, so 
normal maintenance tests do not run on this Packet Interface.
1. Use reset packet-interface location to reset the Packet 
Interface. For repair procedures, see 
on page 1836, the Packet Interface Reset test.
1335
ABRT
Internal IPSI error. The test is on standby IPSI’s Packet Interface module, 
so this test is not allowed to execute.
1. Use set ipserver-interface location to make the standby 
Packet Interface active.
2. Run the test.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABRT
Internal system error
1. Retry the command.
NO 
BOARD
The IPSI circuit pack’s Packet Interface module is administered, but is 
not detected as physically present.
1. If the IPSI circuit pack is present, replace it.
2. If the IPSI circuit pack is not present, insert a TN2312AP IPSI circuit 
pack in the administered slot, and rerun the test.
 1 of 4