Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1834 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1336
ABRT
Internal system error.
1. Use set ipserver-interface location to make the standby 
Packet Interface active.
2. Run the test.
1337
ABRT
The test is not allowed to run because a PNC interchange is in progress. A 
PNC interchange may have been initiated with reset pnc 
interchange
, or as part of a recovery action.
1. Wait 3 minutes and retry the command.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABRT
Internal system error
1. Retry the command.
NO 
BOARD
The IPSI circuit pack’s Packet Interface module is assigned, but is not 
detected as physically present.
1. If the IPSI circuit pack is present, replace it.
2. If the IPSI circuit pack is not present, insert a TN2312AP IPSI circuit 
pack in the assigned slot, and rerun the test.
Table 673: Test #888 Active-Standby Peer Link Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3