Avaya 03-300430 User Manual
PNC-DUP (PNC Duplication)
Issue 1 June 2005
1855
Enabling and Removing PNC Duplication
Note:
Note:
PNC duplication requires IPSI duplication.
To Enable PNC Duplication
To enable PNC duplication:
1. Enable PNC-DUP on the change system-parameters customer-options screen.
2. Fully administer duplicate fiber link connectivity. Verify by issuing list fiber-link. For
2. Fully administer duplicate fiber link connectivity. Verify by issuing list fiber-link. For
IP Duplication go to Step
3. Fully administer IPSI duplication (ipserver-interface duplication). Verify by using
list ipserver-interface.
4. Turn on PNC-DUP using the change system-parameters duplication screen. This
is not allowed if any component of either PNC (A or B) is busied out.
5. The system must insert all connectivity-related components for both standby and active
PNC. For CSS configurations this takes up to 5 minutes depending upon CSS circuit pack
insertion. For Direct Connect configurations this is declared complete at 5 minutes after the
first appearance of the terminal login prompt.
insertion. For Direct Connect configurations this is declared complete at 5 minutes after the
first appearance of the terminal login prompt.
6. The PNC-DUP initialization anti-thrashing timer must expire (this occurs 5 minutes after
completion of board insertion, PNC interchange, or system reset of level 2 or higher).
To Disable PNC Duplication
To disable PNC duplication perform the following sequence of steps:
1. Verify that the A-PNC is active. A forced interchange may be required. See reset pnc in
Chapter 8.
2. Busyout the standby PNC (B-PNC).
3. Turn off the system parameter for PNC-DUP using change system-parameters
duplication.
After PNC duplication has been removed, configuration audits generate the alarm shown
below and possibly others. To clear this alarm, the B-PNC fibers, circuit packs in switch
node carriers (EIs, SNIs, SNCs, and DS1Cs), and switch node carriers must be removed as
outlined in the following steps.
After PNC duplication has been removed, configuration audits generate the alarm shown
below and possibly others. To clear this alarm, the B-PNC fibers, circuit packs in switch
node carriers (EIs, SNIs, SNCs, and DS1Cs), and switch node carriers must be removed as
outlined in the following steps.
01D SN_CONF 5000 255
In this case, 01D is the B-PNC switch node from which duplication was removed.
In this case, 01D is the B-PNC switch node from which duplication was removed.