Error log entries and test-to-clear values
Table 687: POW-SUP Hardware Error Log 
Error
Type
Aux
Data
Associated test
Alarm
level 
1
1. This is a MINOR alarm if there is a redundant power supply, and a MAJOR alarm if there is only one 
power supply.
On/Off
board
Test-to-clear value
1 (
Any
Power supply detection test 
(#1535)
MAJ
MIN 
ON
test environment location
test board location 
recycle carrier location [override]
23 (
Power supply recycle test 
(#1534)
WRN
ON
test environment location
test board location
recycle carrier location [override]
257 (
Power supply recycle test 
(#1534)
MAJ
MIN 
ON
test environment location
test board location
recycle carrier location [override]
513 (
Power supply voltage test 
(#1536) 
MAJ
MIN 
ON
test environment location
test board location
recycle carrier location [override]
769 (
Power supply voltage test 
(#1536) 
MAJ 
MIN 
ON
test environment location
test board location
recycle carrier location [override]
1025 (
)
Power supply voltage test 
(#1536) 
MAJ
MIN 
ON
test environment location
test board location
recycle carrier location [override]
1281 (
Power supply voltage test 
(#1536) 
MAJ
MIN
ON
test environment location
test board location
recycle carrier location [override]
1537 (
Any
Power supply voltage test 
(#1536) 
MAJ
MIN
ON
test environment location
test board location
recycle carrier location [override]
1793 (
Any
Power supply voltage test 
(#1536) 
MAJ
MIN
ON
test environment location
test board location
recycle carrier location [override]
2049 (
Power supply voltage test 
(#1536)
MAJ
MIN
ON
test environment location
test board location
recycle carrier location [override]