Avaya 03-300430 User Manual

Page of 2574
PPP-PT (Control LAN Packet/Port)
Issue 1 June 2005
1895
 
2. See 
on page 1898 for repair 
procedures to verify repair.
3. Clear the alarm (test port location long clear).
d. Error Type 513: PPP link lost end-to-end connectivity.
1. Test for hardware problem (test port location long).
2. Run 
on page 1897, and refer to repair procedures if 
there is a hardware problem.
If there is no hardware problem, the switch tries to re-establish PPP link.
e. Error Type 769: Port received an invalid frame, which is greater than the maximum length, 
contains CRC errors, and/or violates the link level protocol.
1. Test the port (test port location long).
2. Refer to 
3. Clear the alarm (test port location long clear).
f. Error Type 1281: the far end has requested a disconnect of a session on this link. This is a 
log-only error.
g. Error Type 1537, 1538: some or all port sessions (sockets) are down:
1. Test the port (test port location short).
2. See 
on page 1902 for repair procedure to verify repair.
h. Error Type 1793-1920: a socket was closed due to an error. Error Type indicates the 
application associated with this socket; Aux Data indicates the internal application number.
If the switch indicates that:
Then it:
Some of the sessions are down
Raises off-board WARNING
Every session is down
Raises off-board MINOR alarm
Error Type
Application
1793
Unused
1794
DCS
1795
AUDIX
1796
CMS
1797
ISDN Gateway
1798–1920
Reserved for future