Avaya 03-300430 User Manual

Page of 2574
PPP-PT (Control LAN Packet/Port)
Issue 1 June 2005
1899
 
Table 693: Test #1275 SCOTCH Synchronous Loop-Around Test 
Error
Code
Test
Result
Description / Recommendation
1000
ABRT
The port is in use or PPP link is connected.
1. Use status clan-port location to determine when the port is 
available for testing.
2. Use busyout port location to force the port to the idle state.
This command is destructive, causing every call and link using the port to 
be torn down.
1002
ABRT
No TDM bus timeslots available for the test.
1. Retry the command at 1-minute intervals up to 5 times.
1963
ABRT
Firmware indicates that the port is in use or ppp link is connected.
1. Use status clan-port location to determine when the port is 
available for testing.
2. Use busyout port location to force the port to the idle state.
This command is destructive, causing every call and link using the port to 
be torn down.
2000
ABRT
Did not receive circuit pack test response within the allowable time period.
1. If this problem persists, reset the circuit pack (busyout board 
locationreset board location, and release board 
location
).
2. If the problem persists, replace the circuit pack.
2012
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABRT
Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
C-LAN circuit pack detected test failure.
1. If the problem persists, reset the circuit pack (busyout board 
locationreset board location, and release board 
location
).
2. If the problem persists, replace the circuit pack.
PASS
Port circuitry functioning properly.