Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1900 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
TCP/IP Ping Test (#1281)
This nondestructive test fails if the endpoint fails to respond. Use this test to check the circuitry 
in the data path for a peer-to-peer IP layer connection.
Table 694: Test #1281 TCP/IP Ping Test 
Error
Code
Test
Result
Description / Recommendation
1
2
7
11
ABRT
Internal error
1. Retry the command at 1-minute intervals up to 3 times
1005
ABRT
Test configuration is incorrect.
1. Verity PPP link is in-service (status clan-port location or 
status link n).
2. Repeat the test.
1124
ABRT
ppp link is not enabled.
1. Verify that the ppp link is enabled (status port location
status link n, or display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
1125
ABRT
PPP link not in service.
1. Verify whether ppp link is in service (status port location or 
status link n).
2. If the ppp link is not in service, release the link (release link n 
or release port location).
3. Repeat the test.
2000
ABRT
Response to the test was not received from the C-LAN circuit pack 
within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the 
other ports on the board are idle (amber LED is off). Reset the 
circuit pack (busyout board locationreset board 
location
, and release board location).
2. If this result occurs again, replace the circuit pack.
 1 of 2