PRI-CDR (Call Detail Recording Link)
Issue 1 June 2005
1907
 
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 18: the CDR link is busied out and the CDR link is torn down.
c. Error Type 257: Link Retry test (#215) failed. An error was detected when setting up the 
link. See the preceding section 
resolution.
d. Error Type 513: the CDR physical link is down for one of the following reasons:
Cable to the CDR output device is disconnected.
CDR output device is powered off.
The data extension where the CDR output device connects to has been busied out or 
there is a scheduled daily interchange.
1. Check the connectivity of wire and cable among wall jacket, data module, and the CDR 
output device. 
2. Enter status data extension and verify that the data extension of the CDR output 
device is in the in-service/idle state. If the data extension is not available, see 
on page 1906 for resolution. 
Table 697: CDR Link Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm 
Level
On/Off
Board
Test to Clear Value
)
0
Any
Any
Any
test cdr-link primary | 
secondary sh
18 (
)
0
busyout cdr-link 
primary|secondary
WRN OFF
release cd-link primary 
| secondary
Any
Link Retry test (#215)
MIN
1
 
WRN
1. Minor alarms may be downgraded to Warning alarms based on the value used in set options.
OFF
test cd-link primary | 
secondary l
test cdr-link primary | 
secondary
1025 (
1281 (
Any