PS-RGEN (Power supply ring generator)
Issue 1 June 2005
1913
 
Notes:
a. Error Type 1: ring generator interchange failed. Run test environment long. Run 
test board long.
b. Error Type 257: ring voltage not detected on backplane.
c. Error Type 513: ring generator operational status failure. Aux Data values give description 
(values may be added together).
257 (
Ring generator status 
test (#1540)
MAJ
ON
test environment location
test board location 
512
1
513 (
)
Any
Ring generator status 
test (#1540)
MAJ 
MIN
ON
test environment location
test board location 
769
64
Ring generator status 
test (#1540)
MAJ
MIN
ON
test environment location
test board location 
1025
64,
65
Ring generator 
interchange test 
(#1539)
MAJ
MIN
ON
test environment location
test board location 
1. This is a minor alarm if there is a redundant power supply, and a major alarm if there is only one power 
supply. 
Aux Data
Description
1
Overload
2
Shorted
4
Internal fault
8
Commanded off
16
When redundant power supplies are 
present, the standby ring generator (slot 15) 
is providing ringing voltage
32
No ringing voltage on backplane
Table 701: PS-RGEN Error Log Entries (continued)
Error
Type
Aux 
Data
Associated test
Alarm
level
On/Off
 board
Test-to-clear value
 2 of 2