Communication Manager Maintenance-Object Repair Procedures
1918 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
RANL-STA (Remote Analog Line (Station) Port)
S8700 | 8710
 / 
S8500
A per-port instance of this MO (RANL-STA) is used to maintain the circuitry associated with a 
port which has been translated as analog station.   The combo blade circuit board has the 
capability of having two instances of this type of MO.
Failures of the neon message waiting lamp power and the common ringing application circuitry 
are reported as part of common port circuit pack errors; see errors 1281 and 1793 in 
Ringing Caused by Maintenance Testing
Test #48 may cause some terminal equipment to ring briefly during daily maintenance. If this 
ringing disturbs the customer or the terminal equipment, disable it in the Tests field of the 
change station extension screen. This also disables Test 35 on that station.
Error Log Entries and Test to Clear Values
MO Name in 
Alarm Log
Alarm
Level
Initial SAT Command to Run
Full Name of MO
RANL-STA
MIN
test port location l
Remote Analog Line Port
RANL-STA
WRN
test port location sh
Remote Analog Line Port
Table 704: Analog Line Error Log Entries 
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0 (
0
Any
Any
Any
test port location sh r 1
1 (
40960
40975
40977
none
15 (
)
Any
Audits and 
Updates test 
(#36)