Avaya 03-300430 User Manual

Page of 2574
RDIG-STA (Remote Digital Station)
Issue 1 June 2005
1931
 
Possible reasons for no terminal download include:
Terminal is off-hook.
Terminal detected a bad checksum.
Terminal detected a bad or missing EEPROM (refer to Hardware Error Log).
Terminal is busy programming data from a previous PROGRAM message.
Terminal is in the Programming Disabled state.
Terminal is in the Local Program Options mode.
Terminal is disconnected or out of service (use status station).
Table 709: Digital Line Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0 (
)
0
Any
Any
Any
test port location sh r 1
1 (
)
1 – 20, 
40987
None
WRN
OFF
0
busyout port 
location
WRN
OFF
release port location
257 (
)
40971
None
513 (
)
0
Station (Digital) 
Audits #17)
WRN
OFF
test port location sh r 6
767 (
)
40964
None
WRN
OFF
769 (
)
40963, 
40988
None
WRN
OFF
1025 (
None
WRN
OFF
1281
Any
Station (Digital) 
Audits (#17)
WRN
OFF
test port location sh r 4
1537 (
40968
None
WRN
OFF
2304 (
None
2305 (
)
32770, 
40967
None
2817 (
Hyperactive
MIN
OFF
3840 (
40965, 
40989
None
3841 (
41029
None