Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1938 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Table 712: Test #17 Station (Digital) Audits Test 
Error
Code
Test
Result
Description / Recommendation
1
ABRT
Switchhook audit timed out.
1. Make sure voice terminal is connected and repeat test.
2. If test fails, replace voice terminal and repeat test.
2
ABRT
ID request fails, health bit returned from voice terminal is bad.
1. Make sure voice terminal is connected and repeat test.
2. If test fails, replace voice terminal and repeat test.
3
ABRT
The EPF has detected an overcurrent condition.
1. Use test WRN long. If Test #11 passes, then the EPF condition 
was cleared. Rerun the short test sequence. If Test #11 does not pass, 
follow the repair procedures described for Test #11.
2. Look for Error Type 769 logged against RDIG-STA, and follow the 
procedures in the associated footnote. If any additional problems are 
found, rerun the test.
4
ABRT
Internal system error
1. Resolve any outstanding circuit pack maintenance problems.
2. Retry the command at 1-minute intervals up to 5 times.
5
ABRT
Ringer update aborted due to station being in ready-for-service or 
out-of-service state.
6
ABRT
This port may have been busied out by a system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If 
this error is present, use release station to release the port.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 2