Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1980 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each appropriate test’s description, and follow its recommended 
procedures.
b. Error Type 1: an in-line failure of the on-board microprocessor/PSS handshake has 
occurred. Refer to Test #168 for repair procedures.
c. Error Type 130: the circuit pack been removed or has been insane for more than 11 
minutes. To clear the error, reinsert or replace the circuit pack.
d. Error Type 2049: a transient error that does not cause an alarm can occasionally occur 
during a server, TDM bus, or Tone-Clock interchange. Test the port, and follow the 
instructions for the Conference test (#7).
e. Error Type 3840: this error is not service-affecting, and no action is required.
18
0
busyout port location
WRN
OFF
release port location
130 (
)
None
WRN
ON
test port location sh
257
Speech Synthesis PSS Handshake 
test (#168)
MAJ
ON
test port location sh r 2
513
17922
Speech Synthesis Memory test 
(#166)
MIN
ON
test port location sh r 2
769
17664
Speech Synthesis DTMF Receiver 
Inquiry (#164)
MIN
ON
test port location sh r 2
1025
17670
Speech Synthesis SSD Inquiry test 
(#167)
MIN
ON
test port location sh r 2
1281
Speech Synthesis DSP Tone test 
(#165)
MIN
ON
test port location sh r 2
1537
Speech Synthesis Memory test 
(#166)
MIN
ON
test port location sh r 2
1793
Speech Synthesis DTMF Receiver 
test (#163)
MIN
ON
test port location l r 2
2049 (
Conference Circuit test (#7)
MIN
ON
test port location l r 2
2305
NPE Crosstalk test (#6)
MIN
ON
test port location l r 2
3840 (
Any
None
Table 725: Speech Synthesis Port Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
 2 of 2