Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
1982 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Table 727: TEST #6 NPE Crosstalk Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available. The port may
be busy with a valid call and therefore unavailable for certain tests. Wait
until the port is idle (amber LED is off) before retesting.
be busy with a valid call and therefore unavailable for certain tests. Wait
until the port is idle (amber LED is off) before retesting.
1. If the port is idle, retry the command at 1-minute intervals up to 5 times.
1001
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABRT
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-service.
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5
times.
1004
ABRT
The port was seized by a valid call during the test and the test has been
aborted. Wait until the port is idle (amber LED is off) before retesting.
aborted. Wait until the port is idle (amber LED is off) before retesting.
1. Retry the command at 1-minute intervals up to 5 times.
1020
ABRT
The test did not run due to an already existing error on the specific port or a
more general circuit pack error.
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
and attempt to diagnose the already existing error.
2000
ABRT
Response to the test request was not received within the allowable time
period.
period.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 2