Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1984 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1020
ABRT
The test did not run due to an already existing error on the specific port or a 
more general circuit pack error.
2. Examine Error Log for existing errors against this port or the circuit 
pack and attempt to diagnose the already existing error.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1.  Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
The NPE of the tested port did not conference the tones correctly. This 
causes noisy and unreliable connections.
1. Retry the test.
2. If the test continues to fail, then replace the circuit pack.
PASS
The port can correctly conference multiple connections. User-reported 
troubles on this port should be investigated using other port tests and by 
examining the Error Log.
Table 728: TEST #7 Conference Circuit Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2