Communication Manager Maintenance-Object Repair Procedures
2008 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Table 739: TEST #759 Configuration Audit 
Error
Code
Test
Result
Description / Recommendation
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300
ABRT
The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301
ABRT
The software timer could not be set before sending the downlink message 
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2306
ABRT
The SNC circuit pack is not responding to test requests sent by software.
1. Run test led switch-node for the switch node where this board 
resides to verify whether the LEDs on the board light.
2. If the LEDs on the other boards in the carrier light, but the LEDs on 
this board do not light, run test 760 using test board location l 
for the active SNC in this carrier. Wait 5 minutes and then try step 1 
one more time. If the LEDs on this board still do not light, replace this 
board. Replacing an SNC may be service interrupting. See 
on page 2000 for the procedure for 
replacing an SNC.
3. If none of the LEDs light for the boards in the same carrier as this 
board, fix any problems associated with the connectivity of this carrier 
to the server.
a. Check list fiber-link to see the fiber connections to this 
carrier.
b. Check the LEDs on every SNI and EI, and fix any fiber problems.
c. Enter display errors, and follow the repair procedures for any 
EXP-INTF error entries associated with the controlling IPSI 
connected PN.
d. Follow the repair procedures for any SYNC, SNI-BD, SNC-BD, 
FIBER-LK, or SNI-PEER error entries.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.