Avaya 03-300430 User Manual

Page of 2574
SNC-BD (Switch Node Clock Circuit Pack)
Issue 1 June 2005
2017
 
112
FAIL
The SNC circuit pack cannot communicate with the other SNC.
If this test was run on the active SNC and if the switch node carrier is 
administered with duplicate SNCs:
1. If the system originally had duplicate SNCs and the standby SNC was 
removed and never replaced, this error will occur. If you do not intend 
to replace the SNC:
a. Use change circuit-pack to remove the standby SNC from 
administration.
b. If the problem persists, reset the active SNC circuit pack using 
reset board location. If the problem persists after the reset, 
replace the active SNC circuit pack.
2. Use display errors to check the error log. If SNIs in the switch 
node carrier also have problems communicating with the active SNC 
(i.e., error code 257 is logged against SNI-BD), replace the active 
SNC.
3. Replace the standby SNC circuit pack.
4. Retry test board. If this test continues to fail, replace the active 
SNC.
If this test was run on the active SNC and if the switch node carrier is 
administered with only one SNC:
1. Replace the SNC.
If this test was run on the standby SNC:
1. Use display errors to check the error log. If more than one SNI in 
the switch node carrier has problems communicating with the active 
SNC (i.e., error code 257 is logged against SNI-BD), then replace the 
active SNC.
2. Replace the standby SNC circuit pack.
3. Retry test board. Use display errors to check the error log. If 
this error is still in the error log, replace the active SNC.
Table 739: TEST #759 Configuration Audit  (continued)
Error
Code
Test
Result
Description / Recommendation
 10 of 19