Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2056 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 1: the SNI may have trouble communicating with every other SNI and SNC 
circuit pack in the switch node carrier.
1. Replace the SNI circuit pack.
c. Failure audit (#777):The first time you see an SNI-BD error in the error log, run test 
board location. If the failure audit test (#777) fails, enter display errors for this SNI 
circuit pack and continue with the repair procedures for SNI-BD errors.
125 (
None
MIN
ON
257 (
)
Any
Failure audit (#777) 
(
MAJ 
MIN 
WRN
OFF
test board location r 1
513 (
Any
Failure audit (#777) 
(
MAJ 
MIN 
WRN
OFF
test board location r 1
769 (
Any
Failure audit (#777) 
(
MAJ 
MIN 
WRN
OFF
test board location r 1
1025 (
Any
Failure audit (#777) 
(
MAJ 
MIN 
WRN
ON/ OFF
test board location r 1
1281 (
Any
Failure audit (#777) 
(
MAJ 
MIN 
WRN
ON
test board location r 1
1537 (
Any
Failure audit (#777) 
(
MAJ 
MIN 
WRN
OFF
test board location r 1
2561 (
Any
Failure audit (#777) 
(
MAJ 
MIN 
WRN
ON
test board location r 1
2817 (
Any
Failure audit (#777) 
(
MAJ 
MIN 
WRN
ON
test board location r 1
Table 748: SNI Board Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
 2 of 2