Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
2068 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
117
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 17 over the
circuit path.
circuit path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot
17. Use display errors to find any SNI-BD errors and check
display alarms to see if the errors have on-board alarms. Then
display alarms to see if the errors have on-board alarms. Then
follow the repair procedures for SNI-BD.
2. Use display errors to check the error log for other SNI circuit
packs with SNI-PEER Error Type 3073. If other SNI circuit packs have
SNI-PEER Error Type 3073, then replace the SNI in slot 17.
Replacing an SNI may be service interrupting. See
SNI-PEER Error Type 3073, then replace the SNI in slot 17.
Replacing an SNI may be service interrupting. See
on page 2046 for the procedure for replacing an SNI.
If other SNI circuit packs do not have SNI-PEER Error Type 3073 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 17.
118
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 18 over the
circuit path.
circuit path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot
18. Use display errors to find any SNI-BD errors and check
display alarms to see if the errors have on-board alarms. Then
display alarms to see if the errors have on-board alarms. Then
follow the repair procedures for SNI-BD.
2. Use display errors to check the error log for other SNI circuit
packs with SNI-PEER Error Type 3329. If other SNI circuit packs have
SNI-PEER Error Type 3329, then replace the SNI in slot 18.
Replacing an SNI may be service interrupting. See
SNI-PEER Error Type 3329, then replace the SNI in slot 18.
Replacing an SNI may be service interrupting. See
on page 2046 for the procedure for replacing an SNI.
If other SNI circuit packs do not have SNI-PEER Error Type 3329 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 18.
Table 749: TEST #755 SNI Circuit Path Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
9 of 11