119
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 19 over the 
circuit path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 
19. Use display errors to find any SNI-BD errors and check 
display alarms to see if the errors have on-board alarms. Follow 
the repair procedures for SNI-BD.
2. Use display errors to check the error log for other SNI circuit 
packs with SNI-PEER Error Type 3585. If other SNI circuit packs have 
SNI-PEER Error Type 3585, then replace the SNI in slot 19. 
Replacing an SNI may be service interrupting. See 
on page 2046 for the procedure for replacing an SNI.
If other SNI circuit packs do not have SNI-PEER Error Type 3385 errors, 
the problem could be at either of the peer SNI boards. It is arbitrary as to 
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 19.
120
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 20 over the 
circuit path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 
20. Use display errors to find any SNI-BD errors and check 
display alarms to see if the errors have on-board alarms. Follow 
the repair procedures for SNI-BD.
2. Use display errors to check the error log for other SNI circuit 
packs with SNI-PEER Error Type 3841. If other SNI circuit packs have 
SNI-PEER Error Type 3841, then replace the SNI in slot 20. 
Replacing an SNI may be service interrupting. See 
on page 2046 for the procedure for replacing an SNI.
If other SNI circuit packs do not have SNI-PEER Error Type 3841 errors, 
the problem could be at either of the peer SNI boards. It is arbitrary as to 
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 20.
Table 749: TEST #755 SNI Circuit Path Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 10 of 11