SNI-BD (SNI Circuit Pack)
Issue 1 June 2005
2071
 
SNI Off-Board Destructive Facility Test (#756)
This test is destructive.
The SNI runs a destructive loop around of the on-board and off-board Looparound. This test 
returns the result of the off-board loop around, while Test #757 returns the result of the on-board 
loop around.
Table 750: TEST #756 SNI Off-Board Destructive Facility Test 
Error
Code
Test
Result
Description / Recommendation
1015
ABRT
The system will not allow this test to be run because the SNI circuit pack 
has not been busied out. Use busyout board to busyout the SNI circuit 
pack. Repeat test board location long.
1415
ABRT
The lightwave transceiver is absent.
1. If a lightwave transceiver should not be present, do nothing. For 
example, an SNI connected to a DS1C circuit pack or an SNI with a 
metallic connection does not have a lightwave transceiver. This test 
can only be run when a lightwave transceiver exists.
2. Otherwise, check the lightwave transceiver connections.
3. If OK, replace the lightwave transceiver. If a fiber out of frame 
condition exists and lightwave transceivers are used, check that the 
lightwave transceivers are of the same type, that is, both are 9823a or 
both are 9823b. If they are not the same type, replace one of the 
lightwave transceivers:
9823a is used for distances up to 4900 feet.
9823b is used for distances up to 25,000 feet.
4. If the test continues to abort, replace the SNI circuit pack.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300
ABRT
The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301
ABRT
The software timer could not be set before sending the downlink message 
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.