Avaya 03-300430 User Manual

Page of 2574
SNI-BD (SNI Circuit Pack)
Issue 1 June 2005
2073
 
SNI Destructive Facility Test (#757)
This test is destructive.
The SNI runs a destructive loop around of the off-board and on-board loop around. This test 
returns the result of the on-board loop around, while test 756 returns the result of the off-board 
loop around.
0
NO
BOARD
No board was detected by the test.
1. Check that board is properly translated and inserted.
2. Run the test again. If it fails, reset the board. An SNI should be reset 
instead of reseating the circuit pack. The reset board command 
should almost never be used on an SNI. It may be necessary to use 
reset board if the SNI circuit pack gets into a mode where it cannot 
communicate with software. If an SNI with active errors and alarms is 
reset, the errors and alarms may take a while to come back, therefore 
reset board can mask real problems.
3. Run the test again. If it fails, the ID chip on board may be bad. 
Replace the board and retest.
Table 750: TEST #756 SNI Off-Board Destructive Facility Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 3 of 3
Table 751: TEST #757 SNI Destructive Facility Test 
Error
Code
Test
Result
Description / Recommendation
1015
ABRT
The system will not allow this test to be run because the SNI circuit pack 
has not been busied out. Busyout the SNI circuit pack with busyout 
board. Repeat test board location long.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300
ABRT
The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
 1 of 3